5-43
P02, P03
Motor Parameters (Rated capacity and Rated current)
Sets the nominal rated capacity that is denoted on the rating nameplate of the
motor.
P09
Motor Parameters (Slip compensation gain)
Sets the gain to compensate for the motor slip frequency. It is based on the typical
slip of every inverter model as 100%. Set the compensation gain watching the
motor speed.
All the date listed below is applicable to the motors regardless to their output ca-
pacity.
Typical rated slip frequencies for 100%
Rated capacity
(HP/kW)
Fuji standard
8-series (Hz)
Typical motors
rated in HP
(Hz)
Fuji standard
6-series (Hz)
Other motors
(Hz)
0.1/0.06
1.77 2.50 1.77 1.77
0.12/0.1
1.77 2.50 1.77 1.77
0.25/0.2
2.33 2.50 2.33 2.33
0.5/0.4
2.40 2.50 2.40 2.40
1/0.75 2.33 2.50 2.33 2.33
2/1.5 2.00 2.50 2.00 2.00
3/2.2 1.80 1.17 1.80 1.80
5/3.7 1.93 1.50 1.93 1.93
For this function which is related with the motor characteristics, the volt-
age at the base frequency (F05) and motor parameters (P codes) should
be also set consistently.
P99
Motor Selection
To use automatic control features (e.g., the auto torque boost/auto energy saving
and slip compensation) or overload protection for the motor (electronic thermal), the
inverter invokes the parameters and characteristics of the motor. To match the
driving characteristics between the inverter and motor, set the motor characteristics
with this function code and set H03 to "2" to initialize the motor parameter. This
action automatically updates the data of function codes P03, P09 and the constants
used inside the inverter.
Motors P99
=
Fuji standard 8-series (currently standard models)
0
Fuji standard 6-series (conventional models)
3
Other motors or unknown models
4
• For other motors, the parameters for Fuji 8-series motors are appli-
cable.
• The inverter also supports motors rated by HP (Horse Power: typical in
North America, P99 = 1).
Summary of Contents for Frenic Mini FRN001C1E-2U
Page 85: ...5 4 ...
Page 88: ...5 7 ...
Page 89: ...5 8 C codes Control Functions of Frequency ...
Page 92: ...5 11 J codes Application Functions y codes Link Functions ...
Page 167: ...8 6 8 3 Common Specifications ...
Page 168: ...8 7 ...
Page 171: ...8 10 8 5 External Dimensions 8 5 1 Standard models ...
Page 172: ...8 11 ...
Page 173: ...8 12 8 5 2 Models available on order EMC filter built in type ...
Page 174: ...8 13 ...
Page 192: ...MEMO ...
Page 193: ...MEMO ...
Page 194: ...MEMO ...
Page 196: ...Fuji Electric FA Components Systems Co Ltd Fuji Electric Corp of America 2007 06 F07 F07 00CM ...