Keylock
A keylock can be selected to prevent the settings from being inadvertently changed on the
control panel. As long as the keylock is active
-
no settings can be made on the control panel
-
only parameter settings can be retrieved
-
any assigned "Save" button can be retrieved provided that an assigned "Save" button
was selected when the keylock was enabled
Activate/deactivate the keylock as follows:
Keylock activated:
The message "CLO | SEd" appears on the displays.
Keylock deactivated:
The message "OP | En" appears on the displays.
Press and hold the "Mode" button
Press the "Parameter selection" button (right)
Release the "Mode" and "Parameter Selection" buttons
1