51
EN
Single-phase operation
Single-phase op-
eration
As an alternative to three-phase operation, the multivoltage variant (MV) of the power
source enables a welding operation with limited power or duration from just a single-phase
supply. The maximum possible welding power is limited due to the dimensioning of the
mains fuse protection, upon which the safety cut-out of the power source is dependant.
If the mains cable has a 20 A or 30 A fuse, the FUS parameter may be changed to 20 A or
30 A. Welding with a higher maximum power or for longer periods is therefore possible.
The FUS parameter is in the level 2 Setup menu and can be set for a single-phase supply
as well as to a US setting (SEt parameter to US).
In order to use the power source in single-phase operation, the following prerequisites
must be fulfilled:
-
Correct single-phase power source supply in accordance with the chapter "Installation
and commissioning," section "Connecting the mains cable" - "Fitting the strain-relief
device, single-phase operation."
The following table shows which mains voltages and fuse values limit the welding current
in single-phase operation:
The welding current data applies at an ambient temperature of 40°C (104°F).
At a mains voltage of 240 V and a fuse value of 30 A the maximum value of 220 A for the
MIG/MAG welding for instance is possible at a duty cycle of 40 %.
Mains voltage
Fuse value
Welding current limitation
230 V
10 A
MIG/MAG welding:
max. 170 A; 100 A at 100%*
MMA welding:
max. 140 A; 100 A at 100%*
230 V
13 A
MIG/MAG welding:
max. 160 A; 150 A at 100%*
MMA welding:
max. 140 A; 120 A at 100%*
230 V
16 A
MIG/MAG welding:
max. 180 A; 145 A at 100%*
MMA welding:
max. 150 A; 130 A at 100%*
240 V
15 A
MIG/MAG welding:
max. 180 A; 145 A at 100%*
MMA welding:
max. 150 A; 125 A at 100%*
240 V
20 A
MIG/MAG welding:
max. 200 A; 160 A at 100%*
MMA welding:
max. 180 A; 140 A at 100%*
240 V
30 A
MIG/MAG welding:
max. 220 A; 175 A at 100%*
MMA welding:
max. 180 A; 140 A at 100%*
* The 100% values relate to welding with no time limits and without cooling breaks
Summary of Contents for TransSteel 2500c
Page 2: ...2...
Page 4: ...4...
Page 8: ...8...
Page 20: ...20...
Page 21: ...General information...
Page 22: ......
Page 29: ...Control elements and connections...
Page 30: ......
Page 39: ...Installation and commissioning...
Page 40: ......
Page 49: ...49 EN 3 4 3 4 IMPORTANT Tie the phase conductors near the luster terminal using cable ties...
Page 63: ...Welding...
Page 64: ......
Page 77: ...77 EN Number 3 Number 4 Number 5...
Page 78: ...78...
Page 79: ...Setup settings...
Page 80: ......
Page 93: ...Troubleshooting and maintenance...
Page 94: ......
Page 105: ...105 EN Disposal Dispose of in accordance with the applicable national and local regulations...