Troubleshooting
General
The devices are equipped with an intelligent safety system. This means that to a large ex-
tent it has been possible to dispense with melting-type fuses. Melting-type fuses therefore
no longer need to be replaced. After a possible malfunction has been remedied, the device
is ready for use again.
Safety
Fault diagnosis
Make a note of the serial number and configuration of the device and contact our After-
Sales Service team with a detailed description of the error, if
-
errors occur that are not listed below
-
the troubleshooting measures listed are unsuccessful
Power source has no function
Mains switch is on, but indicators are not lit up
Cause:
There is a break in the mains lead; the mains plug is not plugged in
Remedy:
Check the mains lead, ensure that the mains plug is plugged in
Cause:
Mains socket or mains plug faulty
Remedy:
Replace faulty parts
Cause:
Mains fuse protection
Remedy:
Change the mains fuse protection
Nothing happens when the torch trigger is pressed
Power source mains switch is ON and indicators are lit up
Cause:
Only for welding torches with an external control plug: The control plug is not
plugged in
Remedy:
Plug in the control plug
Cause:
Welding torch or welding torch control line is faulty
Remedy:
Replace welding torch
WARNING!
Work that is carried out incorrectly can cause serious injury or dam-
age. The following activities must only be carried out by trained and qualified per-
sonnel. Observe the safety rules in the power source operating instructions.
WARNING!
An electric shock can be fatal. Before opening the unit
-
Turn the mains switch to the "O" position
-
Unplug the device from the mains
-
Put up an easy-to-understand warning sign to stop anybody inadvertently
switching it back on again
-
Using a suitable measuring device, check to make sure that electrically
charged components (e.g. capacitors) have discharged
CAUTION!
Inadequate PE conductor connections can cause serious injury and
damage. The housing screws provide a suitable PE conductor connection for
earthing (grounding) the housing and must NOT be replaced by any other screws
which do not provide a reliable PE conductor connection.
Summary of Contents for TransSteel 2500c
Page 2: ...2...
Page 4: ...4...
Page 8: ...8...
Page 20: ...20...
Page 21: ...General information...
Page 22: ......
Page 29: ...Control elements and connections...
Page 30: ......
Page 39: ...Installation and commissioning...
Page 40: ......
Page 49: ...49 EN 3 4 3 4 IMPORTANT Tie the phase conductors near the luster terminal using cable ties...
Page 63: ...Welding...
Page 64: ......
Page 77: ...77 EN Number 3 Number 4 Number 5...
Page 78: ...78...
Page 79: ...Setup settings...
Page 80: ......
Page 93: ...Troubleshooting and maintenance...
Page 94: ......
Page 105: ...105 EN Disposal Dispose of in accordance with the applicable national and local regulations...