Options
VRD: safety func-
tion
A Voltage Reduction Device (VRD) is an optional safety device for reducing the voltage. It
is recommended for environments in which the risk of an electric shock or electrical acci-
dent is increased considerably during arc welding:
-
Due to a low human body resistance of the welder
-
If the welder is exposed to a clear risk of touching the workpiece or other parts of the
welding circuit
A low human body resistance is possible when there is:
-
water in the area
-
humidity
-
heat, particularly ambient temperatures in excess of 32°C (89.6°F)
In wet, damp or hot locations, humidity or sweat can significantly reduce the skin resistance
and the insulation resistance of protective equipment and clothing.
Such environments can include:
-
Temporary dams for draining certain areas of a site during construction work (coffer-
dams)
-
Trenches
-
Mines
-
Rain
-
Areas partly submerged by water
-
Spraywater areas
The VRD option reduces the voltage between the electrode and the workpiece. In safe
conditions, the indicator for the currently selected welding process is permanently lit. A
safe condition is defined as follows:
-
The output voltage in an open circuit is limited to 35 V.
For as long as the welding operation is active (welding circuit resistance < 200 Ohm), the
indicator of the currently selected welding process flashes and the output voltage may ex-
ceed 35 V.
VRD: safety prin-
ciple
The welding circuit resistance is greater
than the minimum human body resistance
(greater than or equal to 200 Ohm):
-
VRD is active
-
Open circuit voltage is limited to 35 V
-
Unintentional contact with the output
voltage does not put the welder at risk
The welding circuit resistance is less than
the minimum human body resistance (less
than 200 Ohm):
-
VRD is inactive
-
Output voltage not restricted in order to
ensure sufficient welding power
-
Example: Welding starts
Summary of Contents for TransSteel 2500c
Page 2: ...2...
Page 4: ...4...
Page 8: ...8...
Page 20: ...20...
Page 21: ...General information...
Page 22: ......
Page 29: ...Control elements and connections...
Page 30: ......
Page 39: ...Installation and commissioning...
Page 40: ......
Page 49: ...49 EN 3 4 3 4 IMPORTANT Tie the phase conductors near the luster terminal using cable ties...
Page 63: ...Welding...
Page 64: ......
Page 77: ...77 EN Number 3 Number 4 Number 5...
Page 78: ...78...
Page 79: ...Setup settings...
Page 80: ......
Page 93: ...Troubleshooting and maintenance...
Page 94: ......
Page 105: ...105 EN Disposal Dispose of in accordance with the applicable national and local regulations...