23
EN
General
Device concept
The TransSteel (TSt) 2500c, 2700c and
3500c power sources are completely digiti-
sed, microprocessor-controlled inverter po-
wer sources.
The modular design and potential for sys-
tem add-ons ensure a high degree of flexi-
bility. The devices are designed for the
welding of steel.
All devices are suitable for:
-
MIG/MAG welding
-
MMA welding
Functional princi-
ple
The central control and regulation unit of the power sources is coupled with a digital signal
processor. The central control and regulation unit and signal processor control the entire
welding process.
During the welding process, the actual data is measured continuously and the device re-
sponds immediately to any changes. Control algorithms ensure that the desired target
state is maintained.
The device has a "Power limitation" safety feature. This means that the power source can
be operated at the power limit without compromising process safety.
This results in:
-
a precise welding process
-
a high degree of reproducibility of all results
-
excellent weld properties.
Application areas
The devices are used in workshops and industry for manual applications with classical
steel and galvanised sheets.
The TSt 2500c and TSt 2700c power sources are primarily used in light-gauge steel sheet
(light steelwork) applications. Repair, maintenance, and assembly work in shipyards, au-
tomotive suppliers, workshops or the furniture construction industry are among the typical
application areas. The TSt 2500c et TSt 2700c power sources thus position themselves in
their power category between the trade/workshop sector and the industry sector.
The TSt 3500c power sources are designed for:
-
Machine and equipment construction
-
Steelwork
-
Plant and container construction
-
Metal and gantry construction
-
Rail vehicle construction
Summary of Contents for TransSteel 2500c
Page 2: ...2...
Page 4: ...4...
Page 8: ...8...
Page 20: ...20...
Page 21: ...General information...
Page 22: ......
Page 29: ...Control elements and connections...
Page 30: ......
Page 39: ...Installation and commissioning...
Page 40: ......
Page 49: ...49 EN 3 4 3 4 IMPORTANT Tie the phase conductors near the luster terminal using cable ties...
Page 63: ...Welding...
Page 64: ......
Page 77: ...77 EN Number 3 Number 4 Number 5...
Page 78: ...78...
Page 79: ...Setup settings...
Page 80: ......
Page 93: ...Troubleshooting and maintenance...
Page 94: ......
Page 105: ...105 EN Disposal Dispose of in accordance with the applicable national and local regulations...