113
EN
TSt 3500c
1)
Interface to a 230/400 V, 50 Hz public grid
Mains voltage (U
1
)
3 x
380 V
400 V
460 V
Max. effective primary current (I
1eff
)
15.2 A
14.5 A
12.7 A
Max. primary current (I
1max
)
23.9 A
23.0 A
20.1 A
Mains fuse
35 A slow-blow
Mains voltage tolerance
-10 / +15 %
Mains frequency
50/60 Hz
Cos phi (1)
0.99
Max. permitted mains impedance Z
max
at PCC
1)
77 mOhm
Recommended earth-leakage circuit breaker
Type B
Welding current range (I
2
)
MIG/MAG
10 - 350 A
Rod electrode
10 - 350 A
Welding current at
10 min / 40 °C (104 °F)
40 %
60 %
100 %
350 A
300 A
250 A
Output voltage range according to standard characteristic (U
2
)
MIG/MAG
14.5 - 38.5 V
Rod electrode
20.4 - 35.0 V
Open circuit voltage (U
0
peak / U
0
r.m.s)
60 V
Apparent power at 400 V AC
15.87 kVA
Degree of protection
IP 23
Type of cooling
AF
Insulation class
B
Overvoltage category
III
Pollution level according to IEC60664
3
Safety symbols
S, CE, CSA
Dimensions l x w x h
747 x 300 x 497 mm
29.4 x 11.8 x 19.6 in.
Weight
36 kg / 79.4 lb.
Max. shielding gas pressure
5 bar / 72.52 psi
Coolant
Original Fronius
Wire feed speed
1 - 25 m/min / 40 - 980 ipm
Wire drive
4-roller drive
Wire diameter
0.8 - 1.6 mm / 0.03 - 0.06 in.
Wirespool diameter
max. 300 mm / max. 11.81 in.
Wirespool weight
max. 19.0 kg / max. 41.9 lb.
Efficiency at 250 A and 26.5 V
89 %
Max. noise emission (L
WA
)
72 dB (A)
Summary of Contents for TransSteel 2500c
Page 2: ...2...
Page 4: ...4...
Page 8: ...8...
Page 20: ...20...
Page 21: ...General information...
Page 22: ......
Page 29: ...Control elements and connections...
Page 30: ......
Page 39: ...Installation and commissioning...
Page 40: ......
Page 49: ...49 EN 3 4 3 4 IMPORTANT Tie the phase conductors near the luster terminal using cable ties...
Page 63: ...Welding...
Page 64: ......
Page 77: ...77 EN Number 3 Number 4 Number 5...
Page 78: ...78...
Page 79: ...Setup settings...
Page 80: ......
Page 93: ...Troubleshooting and maintenance...
Page 94: ......
Page 105: ...105 EN Disposal Dispose of in accordance with the applicable national and local regulations...