108
TSt 2500c MV
Mains voltage (U
1
)
3 x
200 V
230 V
Max. effective primary current (I
1eff
)
16.8 A
14.5 A
Max. primary current (I
1max
)
26.0 A
22.4 A
Mains fuse protection (slow-blow)
25 A
Mains voltage (U
1
)
3 x
380 V
400 V
460 V
Max. effective primary current (I
1eff
)
8.6 A
8.2 A
7.1 A
Max. primary current (I
1max
)
13.2 A
12.6 A
10.9 A
Mains fuse protection (slow-blow)
15 A
Mains voltage (U
1
)
1 x
230 V
240 V
240 V
240 V
Max. effective primary current (I
1eff
)
16.0 A
15.0 A
18.1 A
18.1 A
Max. primary current (I
1max
)
22.3 A
23.9 A
24.9 A
28.1 A
Mains fuse protection (slow-blow)
16 A
15 A
20 A
30 A
Apparent power
5.13 kVA 5.74 kVA 5.98 kVA 6.74 kVA
Mains voltage tolerance
-10 / +15 %
Mains frequency
50 / 60 Hz
Max. permitted mains impedance Z
max
on PCC
1)
142 mOhm
Welding current range (I
2
)
MIG / MAG
10 - 250 A
Rod electrode
10 - 250 A
Welding current range (I
2
) in single-phase operation
MIG / MAG
10 - 220 A
Rod electrode
10 -180 A
Welding current at
10 min / 40°C (104°F)
40%
60%
100%
U
1
= 200 - 230 V:
250 A
200 A
170 A
U
1
= 380 - 460 V:
250 A
200 A
170 A
Welding current in sin-
gle-phase operation at
10 min / 40°C (104°F)
15%
2)
100%
U
1
= 230 V:
Fuse 16 A
180 A
145 A
Welding current in sin-
gle-phase operation at
10 min / 40°C (104°F)
8%
2)
100%
U
1
= 240 V:
Fuse 15 A
180 A
145 A
Welding current in sin-
gle-phase operation at
10 min / 40°C (104°F)
11%
2)
100%
U
1
= 240 V:
Fuse 20 A
200 A
160 A
Welding current in sin-
gle-phase operation at
10 min / 40°C (104°F)
40%
2)
100%
U
1
= 240 V:
Fuse 30 A
220 A
160 A
Output voltage range according to standard characteristic (U
2
)
MIG / MAG
14.5 - 34.5 V
Rod electrode
20.4 - 30.0 V
Output voltage range according to standard characteristic (U
2
) in single-phase operation
Summary of Contents for TransSteel 2500c
Page 2: ...2...
Page 4: ...4...
Page 8: ...8...
Page 20: ...20...
Page 21: ...General information...
Page 22: ......
Page 29: ...Control elements and connections...
Page 30: ......
Page 39: ...Installation and commissioning...
Page 40: ......
Page 49: ...49 EN 3 4 3 4 IMPORTANT Tie the phase conductors near the luster terminal using cable ties...
Page 63: ...Welding...
Page 64: ......
Page 77: ...77 EN Number 3 Number 4 Number 5...
Page 78: ...78...
Page 79: ...Setup settings...
Page 80: ......
Page 93: ...Troubleshooting and maintenance...
Page 94: ......
Page 105: ...105 EN Disposal Dispose of in accordance with the applicable national and local regulations...