100
E-Stop
Cause:
"External stop" has tripped
Remedy:
Remedy the event that triggered the external stop
-St | oP-
Cause:
At the robot interface the flag was not deleted by the robot
Remedy:
Delete the signal robot ready at the robot interface
PHA | SE
Cause:
Phase failure
with TSt 2500c / TSt 2700c in particular:
If the failure occurs during welding, the welding operation stops.
with TSt 2500c MV / TSt 2700c MV in particular:
A single-phase operation with limited power is possible:
When switching on the power source, "PHA | SE1" is displayed in order to
show that a power reduction will be in effect.
If a change in supply from three-phase to single-phase occurs during welding
(display: "PHA | SE1") or from single-phase to three-phase (display: "PH |
ASE 3"), the welding operation stops.
Remedy:
Check the mains fuse, mains cable and mains plug.
Switch off the power source, wait 10 seconds and switch the power source
back on again.
PHA | SE1
Cause:
The power source is operated in single-phase mode.
Remedy:
-
PHA | SE3
Cause:
The power source is operated in 3-phase mode
Remedy:
-
Err | 51
Cause:
Mains undervoltage: The mains voltage has fallen below the tolerance range
Remedy:
Check the mains voltage, if the error keeps recurring, contact the After-Sales
Service
Err | 52
Cause:
Mains overvoltage: The mains voltage has risen above the tolerance range
Remedy:
Check the mains voltage, if the error keeps recurring, contact the After-Sales
Service
EFd 5
Cause:
Incorrect wire-feed unit connected
Remedy:
Connect correct wire-feed unit
EFd 8
Cause:
Overtemperature on the wire-feed unit
Remedy:
Allow wire-feed unit to cool down
Summary of Contents for TransSteel 2500c
Page 2: ...2...
Page 4: ...4...
Page 8: ...8...
Page 20: ...20...
Page 21: ...General information...
Page 22: ......
Page 29: ...Control elements and connections...
Page 30: ......
Page 39: ...Installation and commissioning...
Page 40: ......
Page 49: ...49 EN 3 4 3 4 IMPORTANT Tie the phase conductors near the luster terminal using cable ties...
Page 63: ...Welding...
Page 64: ......
Page 77: ...77 EN Number 3 Number 4 Number 5...
Page 78: ...78...
Page 79: ...Setup settings...
Page 80: ......
Page 93: ...Troubleshooting and maintenance...
Page 94: ......
Page 105: ...105 EN Disposal Dispose of in accordance with the applicable national and local regulations...