32
No.
Function
(1)
"Parameter selection" button (right)
for selecting the following welding parameters and for changing parameters in the
Setup menu
The relevant symbol lights up when a welding parameter is selected.
Arc length correction
for correcting the arc length
Welding voltage in V *)
Before the start of welding, the system automatically displays a standard val-
ue based on the programmed parameters. During welding, the actual value is
displayed.
Dynamic
for influencing the short-circuiting dynamic at the moment of droplet transfer
- ... harder, more stable arc
0 ... neutral arc
+ ... soft, low-spatter arc
Real Energy Input
for displaying the energy applied during the welding operation. **)
(2)
"Parameter selection" button (left)
for selecting the following welding parameters and for changing parameters in the
Setup menu
The relevant symbol lights up when a welding parameter is selected.
Sheet thickness in mm or in.
If the welding current to be selected is not known it is sufficient to enter the
sheet thickness. The required welding current and any other parameters
marked with *) will then be adjusted automatically.
Welding current in A
*)
Before the start of welding, the device automatically displays a standard value
based on the programmed parameters. During welding, the actual value is
displayed.
Wire feed speed in m/min or ipm
*)
(3)
Adjusting dial (right)
for changing the arc length correction, welding voltage and arc-force dynamic pa-
rameters as well as changing parameters in the Setup menu
(4)
Adjusting dial (left)
for changing the sheet thickness, welding current and wire feed speed parameters
as well as changing parameters in the Setup menu
(5)
"Save" buttons (Easy Job)
for saving up to 5 operating points
Summary of Contents for TransSteel 2500c
Page 2: ...2...
Page 4: ...4...
Page 8: ...8...
Page 20: ...20...
Page 21: ...General information...
Page 22: ......
Page 29: ...Control elements and connections...
Page 30: ......
Page 39: ...Installation and commissioning...
Page 40: ......
Page 49: ...49 EN 3 4 3 4 IMPORTANT Tie the phase conductors near the luster terminal using cable ties...
Page 63: ...Welding...
Page 64: ......
Page 77: ...77 EN Number 3 Number 4 Number 5...
Page 78: ...78...
Page 79: ...Setup settings...
Page 80: ......
Page 93: ...Troubleshooting and maintenance...
Page 94: ......
Page 105: ...105 EN Disposal Dispose of in accordance with the applicable national and local regulations...