![FLYGT MAS 711 Installation And Operation Manual Download Page 91](http://html1.mh-extra.com/html/flygt/mas-711/mas-711_installation-and-operation-manual_2311483091.webp)
Step
Action
Result
3
Run the update program by
double-clicking it.
4
Follow the instruction in the program:
• Make sure the unit is connected
and online.
• Close all web browsers
accessing MAS.
• Enter IP number in the topmost
fi
eld (default is 10.0.48.94).
• Enter password for "con
fi
g"
access level. (default is ef56)
• Click Start Upgrade.
Note!
Do
not
interrupt the program,
disconnect or turn off the unit during
the upgrade process!
During the upgrade progress messages
are displayed in the message
fi
eld on
the right. Each upgrade step is set
green when completed and when the
upgrade is
fi
nished the entire message
fi
eld will turn green. The entire process
will take approximately 15-30 minutes.
91