View Operation Data Using the Operator Panel
Step Action
Result
2
• Press OK to reset the present trip
counter.
• Con
fi
rm with OK.
• “Wait” is displayed brie
fl
y, then back
to menu Pump counter runtime
(1.3.1).
• The trip counter is now reset and
the previous value is saved in a list
of the 10 last trip counters.
3
Press down arrow to view the 10
previous trip counters and reset dates.
4
• Go to menu Pump total starts
(1.4) using down arrow.
• Press OK to view the present
value of the start counter (pump
counter starts), that is, the
number of starts since the trip
starts counter last was reset.
Menu Pump counter starts (1.4.1) is
opened.
5
• Press OK to reset the present
start counter.
• Con
fi
rm with OK.
• “Wait” is displayed brie
fl
y, then
back to menu Pump counter starts
(1.4.1).
• The start counter is now reset and
the previous value is saved in a list
of the 10 last start counters.
6
Press down arrow to view the 10
previous start counters and reset
dates.
7
• Go to menu Pump start and stop
(1.5) using down arrow.
• Press OK to view the start time of
the last run period of the pump.
8
• Press right arrow to view the stop
time of the last run period.
• Press right arrow again to view
the run time of the last run period.
9
Press down arrow and repeat the
steps above to view information on the
second to last run period.
Information on the 50 last run periods
is saved.
View Pump
Information
Follow these steps to view pump information:
Step
Action
1
• Go to menu Dataplate info (1.2) using down arrow.
• Press OK to open the information items in the data plate.
Result:
Menu Serial number (1.2.1) is opened.
2
• Press right arrow to view the serial number.
• Move to the next item in the data plate using down arrow.
• Repeat the steps above to view the other items of the data plate.
3
Press Esc to go back to menu Dataplate info (1.2).
124