![FLYGT MAS 711 Installation And Operation Manual Download Page 89](http://html1.mh-extra.com/html/flygt/mas-711/mas-711_installation-and-operation-manual_2311483089.webp)
Compensate for Measurement Er-
Calculate automatically and compensate
Follow these steps to calculate the resistance automatically and compensate for
measurement error due to long leads:
1.
Calculate the resistance automatically by entering the resistivity, cable length and
cross section area into the Calculation help
fi
eld (in Setup – Temp stator ph1 for
example).
2.
For sensors using a common return lead ( wiring for Temp main bearing and Temp
stator ph 1), tick
Shared return lead
.
3.
Click Calculate.
Result
: The calculated value is automatically entered in the Lead resistance
fi
eld.
4.
• Click Update.
• View the result in the (View–) Quick overview.
89