Remote Commands and Syntax
Commands
6
6-13
Table 6-4. Command Summary by Function
Error Mode Commands
ADJOUT?
Returns the adjusted output magnitude and frequency
ERR_REF
Selects the denominator for UUT error calculations.
ERR_REF?
Returns the denominator used to compute UUT error.
INCR Increments
or
decrements the output
MULT
Multiplies the reference by a value and establishes a new reference
NEWREF
Establishes a new reference
OFFSET
Sets and enables or disables an offset
OFFSET?
Returns the value of the present offset
OLDREF
Sets the output to the present reference
OUT_ERR?
Returns the UUT error computed by the Calibrator
REFOUT?
Returns the value of the present reference
SCALE
Activates and deactivates scaling
SCALE?
Returns scaling information
SCAL_ERR?
Returns the value of the scale error if scaling is active
Calibrator Configuration Commands
BRIGHTNESS
Sets the brightness of the GUI display.
BRIGHTNESS?
Returns the brightness setting.
BTYPE
Selects the amplifier type for voltage or current boost
BTYPE?
Returns the amplifier types set for voltage and current boost
CLOCK
Sets the clock/calendar
CLOCK?
Returns the setting of the clock/calendar
CUR_POST
Selects the active binding post for non-boosted current output
CUR_POST?
Returns the active binding post for non-boosted current output
EMULATE
Partially emulates a 5700A or 5720A over the remote interface.
EMULATE?
Returns the state of emulation as set by the EMULATE command.
EXTGUARD
Opens and closes an internal connection between GUARD and LO
EXTSENSE
Opens and closes an internal connection between SENSE and OUTPUT
FORMAT
Restores calibration constants and setups to factory defaults
LIMIT
Sets positive and negative output limits
LIMIT?
Returns the programmed positive and negative output limits
*LRN?
Returns a list of commands that would duplicate the present state
RANGE?
Returns the present output range
RANGELCK
Locks in the present range, or selects autoranging
LCOMP_52120
Sets inductance compensation for attached 52120As
POST_52120
Sets the output terminals for attached 52120As
XFERCHOICE
Sets whether the choice to turn ac/dc transfers off is given on the front
panel GUI for ac V outputs.
XFERCHOICE? Returns
whether
the
choice to turn ac/dc transfers off is given on the front
panel GUI for ac V outputs.
Summary of Contents for 5730A
Page 4: ......
Page 10: ...5730A Operators Manual x ...
Page 12: ...5730A Operators Manual xii ...
Page 14: ...5730A Operators Manual xiv ...
Page 16: ...5730A Operators Manual 1 2 ...
Page 17: ...Introduction and Specifications Introduction 1 1 3 ...
Page 18: ......
Page 52: ...5730A Operators Manual 2 2 ...
Page 58: ...5730A Operators Manual 3 2 ...
Page 124: ...5730A Operators Manual 5 2 ...
Page 136: ...5730A Operators Manual 6 2 ...
Page 216: ...5730A Operators Manual 7 24 ...
Page 218: ...5730A Operators Manual 8 2 ...
Page 222: ...5730A Operators Manual 8 6 ...
Page 248: ...5730A Operators Manual A 26 ...
Page 249: ...B 1 Appendix B ASCII and IEEE 488 Bus Codes ...