48
11.5 MOTOR CONTROLLER MODULE
If possible, record the user’s preferred options before removing the MOTOR CONTROLLER
MODULE. This will allow you to return the machine to the users original programming.
1.
Connect an anti-static wrist strap to ground.
2.
Unplug the harnesses
(A)
Display Module
(B)
Water Valves
(C)
Power Plug
(D)
Pump ground and Cord ground
(E)
Rotor Position Sensor Harness
(F)
Out of Balance and Lid Reed Switch Plug
(G)
Motor/Pump Harness
(H)
Pressure Tube
3.
Ensure the anti-static wrist strap is still connected to ground.
4.
Remove the screw locating the Motor Controller Module to the cover.
5.
Lift the Motor Controller Module up at the pressure sensor end and ease away from the inlet
chamber. When the Motor Controller Module is separated, a small quantity of water will
discharge from the Inlet Chamber and heatsink. This must be dried off before refitting.
Note:
When reassembling ensure console area is dry. For easy assembly lubricate the sealing
grommets with soapy water or liquid detergent.
6.
Connect the Display Module.
7.
Refit Console.
8.
Select the
OPTION ADJUSTMENT
Mode. By doing this, the new position of the Location
switch is programmed into memory. Program the users preferred options.