67
12.
Refit the clamp plate onto the stator and tighten the four 3/8 “ bolts to a torque of 44 in.-lb. (5
Nm).
Note:
The stator should have some slight radial movement on the resilient mounts of
approximately 1/32 “ – 1/16 “ (0.5 – 1mm) when correctly tightened as shown by the arrows on the
diagram below, and should have minimal axial play (rocking movement) of 1/32 “ (0.5mm)
maximum.
13.
Fit the wiring harness into the securing clips.
14.
Fit the rotor onto the shaft and locate it on the spline. Using a 3/8 “ (16mm) socket, tighten the
plastic nut to a torque of 140 in.lb (16 Nm). Hold the rotor stationary until it is secured.
Note:
Care should be taken not to catch fingers between the rotor and the stator.
15.
To refit the pressure chamber plug, moisten the O Ring with water and push into position
(stepped section facing toward the tub). Refit the retaining clips.
16.
Refit the pressure tube and clamp.
17.
Use the hook on the drain hose fixture to clip it over the rim of the tub.
18.
Lift the tub and place inside the cabinet.
19.
Thread the drain outlet hose through the hole in the rear of the cabinet.
20.
Clip in place the right front and back left suspension assemblies.
21.
Unclip the drain hose fixture from the lip of the tub and screw into position on the cabinet.