50
1.
Refer Section 13.3 for motor removal.
2.
Unclip the rotor position sensor Module from the stator and slide it out.
3.
When fitting, line up the arrows on the Rotor Position Sensor and Stator. Slide the Rotor
Position Sensor into the Stator poles until the clip locks into the notch on the other side of the
Stator. Refer diagram Section 11.7.
4.
To refit motor, refer Section 13.3.
11.8 DIAGNOSTIC TEST
I
MPORTANT
After replacement of an electronic component, carry out the following diagnostic functional tests.
1.
Enter
OPTION ADJUSTMENT
Mode to program new Location switch setting into memory.
2.
Select the Diagnostic mode. Check LED’s, Lid switch, Out of Balance switch, Location switch,
Pump test and Water valve test.
3.
If the Re-start or Re-cycle features have been used during the servicing procedure, return these
to the standard factory settings. This can be achieved by unplugging the washer at the wall.
4.
Functional Test. Check basic washer functions, ie fill, agitate, pump out and spin, by running a
short cycle.
11.9 LID SWITCH
1.
Remove Motor Controller Module.
2.
Disconnect the wiring from the Out of Balance switch.
3.
Remove the lid assembly.
4.
Remove the 2 rubber buffers and screws from the front of the cover.
5.
Release the cover retaining clips at the rear of the cabinet.
6.
Tilt the cover back and rest against a wall. The cover is not self supporting on the retaining
clips.
7.
Unclip the reed switch and wiring from retention features in cover.
8.
Assemble in reverse order. Ensure wiring is secured correctly in retention features.