5.
Disconnect Display Module plug (A). Disconnect the motor/pump harness plug (B), Rotor
Position Sensor plug (C). Remove the pump ground lead (D). Remove the power plug (E).
Remove the rubber bungs from the back of the cord set clamp screw holes, undo the 2 screws
which are holding the cord clamp. Feed the ground wire and plug through the cord set clamp
opening.
NOTE:
DO NOT REMOVE THE GROUND CLIP FROM THE CABINET
6.
Remove the two rubber lid buffers and screws from the front of the cover. Release the retaining
clips at rear of cabinet using a flat bladed screwdriver. Lift the cover clear, feeding wiring
through the opening in the corner of the cover.
Note:
The cover cannot be hinged back without first releasing the rear clips from the cabinet and
lifting at the same time.
7.
Unclip the bias spring from the front left suspension rod. Unclip the neck ring from the top of
the tub.
8.
Remove the fabric softener dispenser, unscrew the agitator retaining nut and remove the
agitator.