The shaft can be removed in one direction only, towards the inside of the tub. Remove the shaft
from the tub. Should this shaft be difficult to remove, use pullers and mandrel. Refit the stator
motor clamp plate onto the tub and secure with the stator mounting bolts. Use the stator clamp
plate to hold the legs of the pullers in place.
WARNING:
Make sure the stator clamp plate is still flat before reusing. If in doubt, replace.
26.
Remove the outer bearing using the bearing removal tool. (Refer diagram Section 12).
Warning:
Do not remove the bearings with a hammer and drift as serious damage to the bearing
housing or tub could result.
Use the bearing removal tool as illustrated below.
27.
Remove the seal and inner bearing together using the bearing removal tool.
Insert the threaded rod and extractor washer up from the bottom of the tub. Then place the collar
and large locating spigot on the threaded rod and extract the seal and bearing together.