PRESSURE RANGE MENU (BRUSHES SWEEP MOT)
Proceed as follows to change the “PRESSURE RANGE” parameter in the brush motor menu:
1.
Display the "MACHINE BRUSHES SETTINGS" menu - see
2.
Display the “SERVICE” menu - see
3.
Display the “PARAMETERS” menu - see
“PARAMETERS MENU (SERVICE)” on page 17
4.
Display the “BRUSHES SETS” menu - see
“BRUSHES SETS MENU (PARAMETERS)” on page 34
5.
Display the “SWEEP BRUSH” menu - see
“SWEEP BRUSH MENU (GENERAL SETS)” on page 38
.
6.
Using buttons (1) and (2) (
Fig.1
) select the "PRESSURE RANGE" screen (
Fig.2
).
7.
As soon as the “PRESSURE LEVEL” screen (
Fig.2
) is displayed, select the value of the maximum allowed
range of the current absorbed by the pressure levels before the tripping of the ammeter resistance protection
using buttons (3) and (4) (
Fig.1
).
N.B.:
the selected value will be visible in the text string (5) in the lower part of the screen (
Fig.2
).
8.
Confirm the selection by pressing the button (6) (
Fig.1
).
N.B.:
the selected value will be visible in the text string (5) in the lower part of the screen (
Fig.2
).
8.
Confirm the selection by pressing the button (6) (
Fig.1
).
Brushes
Sweep Mot
45
[A]
Pressure lev. 1:
min:10
max:100
2
5
2
4
1
3
6
1
N.B.:
the “PRESSURE LEVEL” parameter indicates the current absorbed by the sweeping brush head while
working.
N.B.:
the “PRESSURE LEVEL” parameter is expressed in amperes (A). The numerical value is between a
minimum of 10 and a maximum of 100, and the selectable increment is one unit.
N.B.:
the “PRESSURE LEVEL” parameter (Sum) is set in the factory at a value of 30.
Page 41