68
Operation Place
Ah
Linearity
Compensation
Function
0 = Off; 1 = On
Aj
ad value of zero point
(offset), span weight
value, net span AD
value
d1
= as value of zero point. Data length = 8 (integers only) with leading space (Hex code 20).
d2
= span weight value. Data length =8 including decimal with leading space (Hex code 20).
d3
= net span AD value. Data length = Data length = 8 (integers only) with leading space (Hex code 20)
Ak
Weight
unit
enable/disable for kg, g
and lb
d1
= kg: - 0 = Off; 1 = On
d2
= g: - 0 = Off; 1 = On
d3
= lb: - 0 = Off; 1 = On
Al
Filter strength
0 = level 1; 1 = level 2; … ;7 = level 8; 8 = level 9
Am
Initial
Zero
range,
manual zero range,
auto
zero
tracking
speed
d1
= initial zero range: - 0 = Off, 1 = 1%, 2 = 2%; … 5 = 5%; 6 = 10%; 7 = 20%
d2
= manual zero range: - 0 = 1%; 1 = 2%; 2 = 3%; 3 = 4%; 4 = 5%; 5 = 10%; 6 = 20%; 7 = 50%; 8 = 75%; 9 =
100%
d3
= auto zero tracking speed: - 00 = Off; 01 = 0.25e; 02 = 0.50e; 03 = 10e; 04 = 1.5e; 05 = 2.0e; 06 = 2.5e; 07 =
3.0e; ….; 09 = 5e; 10 = 7.5e; 11 = 10e
An
Auto tare, repetitive
tare and preset tare
d1
= auto tare: - 0 = Off; 1 = On; 2= Continuous
d2
= repetitive tare: - 0 = Off; 1 = On
d3
= Preset tare: - 0 = Off; 1 = On
Ao
Stability
control
of
manual
zero
and
manual tare
d1
= manual zero stability control: - 0 = no (disable); 1 = Yes (enable)
d2
= manual tare stability control: - 0 = no (disable); 1 = Yes (enable)
Ap
Auto power off time,
display
brightness,
auto power saving,
keypad buzzer and
system buzzer
d1
= auto power off time: - 0 = Off; 1 = 1 minute; 2 = 3 minute; 3 = 5 minute; 4 = 10 minute; 5 = 20 minute
d2
= display brightness (01 ~ 04). 01 = lowest, 04 = highest.
d3
= auto power saving: - 00 = Off; 01 = On
d4
= keypad buzzer: - 0 = Off; 1 = On
d5
= system buzzer: - 0 = Off; 1 = On
Aq
Check result buzzer,
near zero value, high
limit for weighing, low
limit for weighing, high
limit for counting, low
limit for counting
d1
= check result buzzer: - 0 = Off; 1 = In; 2 = Out; 3 = hi, 4 = lo
d2
= near zero value. Data length = 8 with leading space (Hex code 20)
d3
= Hi Limit for weighing. Integer only. Data length = 8 including decimal with leading space (Hex code 20).
d4
= Lo Limit for weighing. Integer only. Data length = 8 including decimal with leading space (Hex code 20).
d5:
= Hi Limit for counting. Integer only. Data length = 8 (integers only) with leading space (Hex code 20).
d6
: = Lo Limit for counting. Integer only. Data length = 8 (integers only) with leading space (Hex code 20).