18
Near Zero value is useful for dynamic weight check applications to bypass unnecessary LO alarm during uploading and unloading
process.
Notes: -
Value entered valid only when Check function is activated.
Near zero weight value can be any value between 20d and LO limit.
Any near zero value which less than 20d will be ignored. Instrument will deem 20d as minimum near zero weight value.
The HI LO comparison remains non-activated when weight reading is less than the near zero value entered here.
F27
Reserved.
F28
Ask for Operator Number when
Power on
Yes
** No
Yes: - Instrument will ask for operator number during countdown process when power on. Enter 4-digit operator number or
press [CE/x10] to skip operator number when being asked.
No: - Instrument will not ask for operation number.
F29
Read Calibration and parameter set counts.
O (Parameter set count): - shows total times that the parameters of F80~F88 have been altered.
C (Calibration count): - shows total times of calibration.
F30
Allow Letters and Symbols for
Customer & Product Code
Manual Entry
On
** Off
F31
Auto Power Saving
Off
** On