33
9. Action-Tare-Memory (ATM)
9.1 Description of ATM Mode
It means action, then tare, then memory: -
•
Action = load or remove weight from weighing platform.
•
Tare = the above weight added on or removed from will be tare off automatically.
•
Memory = the above weight will be added to or deducted (in case of removal) from accumulated
memory.
9.2 Basic ATM Settings
a.
Refer to
6.6
on how to select the desired weight unit.
b.
Enter ATM mode.
c.
Press and hold
[FUNC/SET]
to select Auto Accumulation target. Then press
[FUNC/SET]
to shift
between one of the below parameters, then press
[PRINT/M+]
to confirm.
•
Gross = Gross weight will be accumulated.
•
Net = Net weight will be accumulated.
d.
Instrument prompts for delay time (second). Delay time is the time interval (00 ~ 99 seconds): -
•
Between a valid stable weight result is obtained and before it is tare off and accumulated to
memory.
•
Display time of total accumulated weight result (after all loadings are removed) and before it is
clear from print out memory.
e.
Enter delay time through numeric keys then press
[PRINT/M+]
to enter.
f.
At this point, ATM mode is ready for use.
9.3 Start using ATM
23
a.
Apply container on platform. Instrument will tare off the weight of the container.
b.
Apply or removed load on or from platform. The weight result is displayed for the time interval set forth
by above point 2. Then instrument will accumulate the weight result in memory then clear it from the
display.
Notes: -
•
Both positive and negative weight will be accumulated to memory.
•
Positive weight will be added to the accumulated memory.
•
Negative weight will be deducted from the accumulated memory.
c.
Apply/remove another load on/from platform. The weight result is displayed for the time interval set forth
by above point 2. Then instrument will accumulate the weight result in memory and clear it from the
display.
d.
Repeat point 3 until all weighing sequence is completed.
e.
To recall current total accumulated weight, press
[MR/UNIT]
.
f.
At this point: -
•
Press
[ZERO]
to quit, or
•
Press
[PRINT/M+]
to print the current accumulated weight.
g.
When all loads are removed from weighing platform. Total accumulated weight value will then be erased
automatically.
9.3.1 Weight check control for ATM
When weight Check Control is in effect, only weights within LO and HI limit will be tare off and accumulated.
23
Weight changed less than 10d will not be processed.