51
Appendix E: - Customizing Lab 2 Print Format
25 variants + 2 commands (
Cr LF and End
) are available for custom print output. Refer to the below
output format variants table
for more detail.
E.1 Print Output Format Variants Table
Variant
Description
Output Sample
End
End of Input
Not Visible
Cr LF
Hex Code 0D 0A
Not Visible
dAtE
Date of Output
Date 2020-03-25
tiME
Time of Output
Time 17:24:04
nEt
Net Weight
Net 15.000kg
tArE
Tare Weight
Tare 0.000kg
GroSS
Gross Weight
Gross 15.000kg
unit.wt
Unit weight
@WT 49.9997g
Count
Number of piece
QTY 400pcs
H rEF
Hi Limit
High 6.000kg
L rEF
Lo Limit
Low 2.000kg
Ani
Weight Hold (Animal Weighing)
Hold.W 0.000kg
Ch rES
Comparison Result
Result Above
trAnS
No. of accumulated transaction
Seq 2
ACC
Total Accumulated Weight
Total_WT 20.000kg
Total Accumulated Count (
Note A
)
Total_QTY 2000pcs
SiGn
Signature Line
________________________
P Code
Product Code
Pcode G2e
Id
Machine ID
Mac 11
GrouP
Machine Group Number
MacGp 22
oPCodE
Operator Number
Opr 8888
C CodE
Customer Code
Name FM
Note A
: This line is generated when all the below conditions are met: -
a.
Instrument is in Piece Count Mode, and
b.
ACC is selected.