22
5.5.4 When comport is set as Auto (Auto 1~3)
1.
Instrument displays baud rate. 9 parameters (1200~256000) are available. Press
[FUNC/SET]
or
[MR/UNIT]
until the preferred parameter appears then press
[PRINT/M+]
to save.
2.
Instrument displays Parity. 3 parameters (None, odd, even) are available. Press
[FUNC/SET]
or
[MR/UNIT]
until the preferred parameter appears then press
[PRINT/M+]
to save.
3.
Instrument displays Data length. 2 parameters (7, 8) are available. Press
[FUNC/SET]
or
[MR/UNIT]
until the preferred parameter appears then press
[PRINT/M+]
to save.
4.
Instrument displays Auto Accumulation. 2 parameters (on, off) are available. Press
[FUNC/SET]
or
[MR/UNIT]
until the preferred parameter appears then press
[PRINT/M+]
to save.
•
On = Auto memory accumulation enable. Instrument will accumulate the printed value to
memory.
•
Off = Auto memory accumulation disable.
5.
Instrument displays Check Control. 2 parameters (on, off) are available. By default, print data will only
be transmitted under all auto print modes. Press
[PRINT/M+]
to save.
•
On = (When check function is in effect) Only OK value (value which is within Lo and Hi Limits)
will be transmitted.
•
Off = (When check function is in effect) Check requirement is disable.
6.
Instrument displays Stability control. 2 parameters (Yes, no) are available
. By default, only stable
value will be transmitted under all auto print modes.
Press
[PRINT/M+]
to save.
7.
Instrument displays minimum output weight. 21 parameters (0d~20d) are available.
By default, only
stable value which is ≥20d under all auto print modes.
Press
[PRINT/M+]
to save.
8.
Instrument displays print format. 7 parameters (Lab 1, Lab 2, Lab 3, Lab 4, Lab 5, LP-50 and TSC).
Instrument will not generate any output if the actual weight is less than the parameter weight selected.
Press
[FUNC/SET]
or
[MR/UNIT]
until the preferred parameter appears then press
[PRINT/M+]
to
save.
•
Lab 1 = Output in Landscape direction. If Lab 1 is selected, refer to
5.5.3.1
for other settings.
•
Lab 2 = Output in Portrait Direction. If Lab 2 is selected, refer to
5.5.3.2
for other settings.
•
Lab 3 = Database output mode.
•
Lab 4 = Journal output format with gross and net weight of each individual transaction. This
format supports weighing, piece count and ATM mode only. If Lab 4 is selected, refer to
5.5.3.3
for other settings.
•
Lab 5 = Journal output format with time and net weight of each individual transaction. This
format supports weighing, piece count and ATM mode only. If Lab 5 is selected, refer to
5.5.3.3
for other settings.
•
LP-50/TSC = Output to LP-50 /TSC label printer. If LP-50/TSC is selected, refer to
5.5.3.4
for
other settings.
9.
At this point, Auto (Auto 1~3) setup is completed.
5.5.5 When Comport 1 is set as Scanner
1.
Instrument displays baud rate. 9 parameters (1200~256000) are available. Press
[FUNC/SET]
or
[MR/UNIT]
until the preferred parameter appears then
[PRINT/M+]
to save.
2.
Instrument displays Parity. 3 parameters (None, odd, even) are available. Press
[FUNC/SET]
or
[MR/UNIT]
until the preferred parameter appears then press
[PRINT/M+]
to save.
3.
Instrument displays Data length. 2 parameters (7, 8) are available. Press
[FUNC/SET]
or
[MR/UNIT]
until the preferred parameter appears then press
[PRINT/M+]
to save.
4.
At this point, scanner setup is completed.