16
F14
Buzzer
Kb (keypad buzzer)
(
**On
/Off)
St (System buzzer)
(
**On
/Off)
F15
Check Result Buzzer & Action
on Negative Value
OFF
** IN
OUT
Hi
Lo
Setting procedures
: -
1.
Set Check Result Buzzer then press
[PRINT/M+]
.
2.
Set Action on Negative Value.
Check Result Buzzer
oFF = Check Buzzer disabled,
IN = Check Buzzer activates when reading is within range.
ouT = Check Buzzer activates when reading is out of range.
Hi = Check Buzzer activates when reading more than Hi limit.
Lo = Check Buzzer activates when reading lower than Lo limit.
Action on Negative Value
Off = Check Mode Disable when Value is less than zero.
** On
= Absolute value, all negative values will be deemed and checked as positive ones.
F16
Set Comport 1
Off
Auto 1
Auto 2
Auto 3
Manual
** PC
Scanner
Refer to F17 for details.
F17
Set Comport 2
Off
Auto 1
Auto 2
Auto 3
Manual
PC
**CMD
Off = No data output.
Auto 1 = auto print when weight is stable.
Auto 2 = the highest stable weight value (of a weighing process) will be automatically printed when all loads are removed
(and gross weight returns to zero or minus).
Auto 3 = the last stable weight value (of a weighing process) will be automatically printed when all loads are removed (and
gross weight returns to zero or minus).
Manual = Manual output to printer or computer.
PC = Continuous / Interval output.
CMD = Command / information request mode and APP mode.
Scaner = Serial scanner.
Notes: -