The emergency stop circuit shown in Fig. 3/9 enables
all possibilities to be used. The reaction of the cylinder
depends on whether you close connection 3 on switch-
ing valves 1.2 and 1.3, or whether you use a silencer or
restrictor valve to connect the compressed air.
Reaction of the
cylinder
Connection 3 of valve 1.2
Connection 3 of valve 1.3
Cylinder pressureless
Connect silencer
Connect silencer
Piston clamped
Close with blind plugs
Close with blind plugs
Right-hand end
position
Connect compressed air
Connect restrictor valve with
silencer
Left-hand end
position
Connect restrictor valve with
silencer
Connect compressed air
3. Installation
SPC-10 9902a
3-23