7
Mass load
Fit the mass load free of play. For possible moving
mass loads see the DIL switch settings for permitted
valve-cylinder combinations and mass loads in Appen-
dix A.
8
Fixed stops
With cylinders of type DGPL-... you can use e.g. the
shock absorber support (without shock absorber) type
KYP-... as a fixed stop. The cushioning path of the in-
ternal end position cushioning (PPV) must not project
into the path of the working stroke.
•
Fit the fixed stops outside the cushioning path (PPV).
1
2
3
Cylinder end position
Permitted end position (example)
Cushioning path of the internal end position cushioning (PPV)
Fig. 3/7: Cushioning path (PPV)
Details on the cushioning length of the cylinder used
can be found in the operating instructions for the cylin-
der and in the Pneumatics Catalogue.
1
3
3
2
2
3. Installation
SPC-10 9902a
3-15