If the SPC-10 is to be used in an environment sub-
jected to heavy electrical interference, the propor-
tional directional control valve must be electrically
insulated from the mounting surface.
Fitting onto moving parts
•
If fitted to moving parts, the proportional directional
control valve must be mounted at right-angles to the
direction of movement. Acceleration forces then have
no influence on the valve slide setting.
1
2
3
Fitting at right-angles to direction of movement
Not permitted
Proportional directional control valve MPYE-5-...-...-
Fig. 3/5: Fitting to moving parts
Use silencers with a large flow rate U-1/8, U-1/4 or
U-3/8.
2
1
3
3. Installation
3-12
SPC-10 9902a