In order to influence the positioning times:
•
increase or reduce the supply pressure within the
permitted range
•
install exhaust restrictors in the exhaust lines of the
proportional directional control valve.
If fluctuations in pressure of over 1 bar occur in front of
the proportional directional control valve, install a com-
pressed air reservoir (see chapter 3). Please observe
the general installation instructions.
5. Diagnosis and error treatment
5-12
SPC-10 9902a