B Reference
paramete
Festo – GDCP-CMMO-ST-LK-C-HP-EN – 2017-05b – English
93
B.3.7
Axis parameters: electric drives 1
Group/name
PNU
Subindex
Type
Mechanical parameters
è
Reversal of direction
(Polarity)
1000
1
int8
Encoder resolution
(Encoder Resolution)
1001
1, 2
uint32
Gear ratio
(Gear Ratio)
1002
1, 2
uint32
Feed constant
(Feed Constant)
1003
1, 2
uint32
Axis parameter
(Axis Parameter)
1005
2, 3
uint32
Homing parameters
è
Offset axis zero point
(Offset Axis Zero Point)
1010
1
int32
Homing method
(Homing Method)
1011
1
int8
Speeds
(Velocities)
1012
1 … 3
int32
Acceleration/deceleration
(Acceleration/Deceleration)
1013
1
int32
Max. torque
(Max. Torque)
1015
1
int16
Speed limit, stop detection
(Block Detection Velocity Limit)
1016
1
int32
Damping time, stop detection
(Block Detection Window Time)
1017
1
uint16