6
Control via FHPP
Festo – GDCP-CMMO-ST-LK-C-HP-EN – 2017-05b – English
65
Overview of parameters and I/Os in direct application of force mode
Parameters involved
Parameter
PNU
FHPP direct mode
è
FHPP setpoint/actual values
523
Settings of the FHPP direct mode
524
Direct mode position
è
Basic value speed
1)
540
Load
544
Force direct mode
è
Message window for force reached
552
Basic value force
555
FHPP direct mode
general
è
Start delay
582
Start condition
583
Electric drives
è
Nominal motor torque
1036
Start (FHPP)
CPOS.START = rising edge: start
CDIR.ABS = absolute/relative setpoint value
CDIR.COM1/2 = control mode
è
Acknowledgement (FHPP)
SPOS.MC = 0: Motion Complete
SPOS.ACK = rising edge: acknowledge start
SPOS.MOV = 1: Drive moves
Requirement
Device control through controller/fieldbus
Motor controller in the status “Operation enabled”
1)
The controller transfers a percentage value in the control bytes, which is multiplied by the base value to get the setpoint value
Tab. 6.11
Parameters and I/Os in direct application of force mode