5
Sequence control and I/O data
42
Festo – GDCP-CMMO-ST-LK-C-HP-EN – 2017-05b – English
5.4
Assignment of the control bytes and status bytes (overview)
Assignment of the control bytes (overview)
CCON
(All)
B7
OPM2
B6
OPM1
B5
LOCK
B4
–
B3
RESET
B2
BRAKE
B1
STOP
B0
ENABLE
FHPP operating mode
selection
Block FCT
access
–
Acknow
ledge
malfunc
tion
Release
brake
Stop
Enable
drive
CPOS
(All)
B7
–
B6
CLEAR
B5
TEACH
B4
JOGN
B3
JOGP
B2
HOM
B1
START
B0
HALT
–
Delete
remain
ing path
Teach
value
Jog neg
ative
Jog posit
ive
Start
homing
Start po
sitioning
task
Halt
CDIR
(Direct
applica
tion)
B7
–
B6
–
B5
XLIM
B4
–
B3
–
B2
COM2
B1
COM1
B0
ABS
–
–
Deactiv
ate stroke
limit
value.
–
–
Control mode
(position, force,
speed, ...)
Absolute/
relative
Tab. 5.12
Overview, assignment of the control bytes
Assignment of the status bytes (overview)
SCON
(All)
B7
OPM2
B6
OPM1
B5
FCT/MMI
B4
VLOAD
B3
FAULT
B2
WARN
B1
OPEN
B0
ENABLED
Feedback on FHPP
operating mode
FCT
device
control
Load
voltage
applied
Fault
Warning
Opera
tion en
abled
Drive
enabled
SPOS
(All)
B7
REF
B6
STILL
B5
FOLERR
B4
MOV
B3
TEACH
B2
MC
B1
ACK
B0
HALT
Drive re
ferenced
Standstill
monito
ring
Following
error
Axis is
moving
Acknow
ledge
teaching
or
sampling
Motion
Com
plete
Acknow
ledge
start
Halt
SDIR
(Direct
applica
tion)
B7
–
B6
–
B5
XLIM
B4
VLIM
B3
–
B2
COM2
B1
COM1
B0
ABS
–
–
Stroke
limit
reached
Speed
limit
reached
–
Feedback control
mode (position,
force, speed)
Absolute/
relative
Tab. 5.13
Overview, assignment of the status bytes