5
Sequence control and I/O data
32
Festo – GDCP-CMMO-ST-LK-C-HP-EN – 2017-05b – English
T
Internal conditions
T5
Deactivate drive
CCON.ENABLE = 0
è
CCON = xxx0.xxx
0
T6
Deactivate drive
CCON.ENABLE = 0
è
CCON = xxx0.xxx
0
T7*
Malfunction recognised.
T8
Reaction to malfunction completed; drive stopped.
T9
There is no longer a malfunction.
It was a serious error.
Acknowledge malfunction
CCON.RESET = 0
}
1
CCON.ENABLE = 0
è
CCON = xxx0.
P
xx0
T10
There is no longer a malfunction.
It was a simple error.
Note: T10 permits acknowledgement of malfunctions
without having to switch off the controller.
Acknowledge malfunction
CCON.RESET = 0
}
1
CCON.ENABLE = 0
è
CCON = xxx0.
P
xx1
T11
Malfunction still exists.
Acknowledge malfunction
CCON.RESET = 0
}
1
è
CCON = xxx0.
P
xxx
1)
Key: P = rising edge (positive), N = falling edge (negative), x = any
Tab. 5.2
Status transitions while achieving ready status
5.2.2
Positioning
In principle: The transitions T4, T6 and T7* always have priority!
T
Internal conditions
TA1
Homing is present.
Start positioning task
CPOS.START = 0
}
1
CPOS.HALT = 1
è
CPOS = 0xx0.00
P1
TA2
Motion Complete = 1
The current record is completed. The next record is not
processed automatically.
None, positioning job has been
completed
TA3
Motion Complete = 0
Positioning job not yet completed.
Trigger intermediate stop
CPOS.HALT = 1
}
0
è
CPOS = 0xxx.xxx
N
Key: P = rising edge (positive), N = falling edge (negative), x = any
Summary of Contents for CMMO-ST-C5-1-LKP
Page 182: ......