B Reference
paramete
Festo – GDCP-CMMO-ST-LK-C-HP-EN – 2017-05b – English
99
PNU 120
Manufacturer’s device name (Manufacturer Device Name)
Subindex 1 … 30
Class: Array
Data type: char
FW …
Access: ro
Reading of the manufacturer’s designation of the drive (ASCII, 7-bit). Example: CMMO-ST-C5-1-LKP.
Unused characters are filled with zero (00
h
=’\0’).
Tab. B.14
PNU 120
PNU 121
User’s device name (User Device Name)
Subindex 1 … 30
Class: Array
Data type: char
FW …
Access: rw1
Reading or writing of the user designation of the drive (ASCII, 7-bit).
Unused characters are filled with zero (00
h
=’\0’).
Tab. B.15
PNU 121
PNU 122
Name of the drive manufacturer (Drive Manufacturer Name)
Subindex 1 … 30
Class: Array
Data type: char
FW …
Access: ro
Reading of the drive manufacturer’s name (ASCII, 7-bit). Fixed: “Festo AG & Co. KG”
Unused characters are filled with zero (00
h
=’\0’).
Tab. B.16
PNU 122
PNU 123
HTTP address of manufacturer (HTTP Drive Catalog Address)
Subindex 1 … 30
Class: Array
Data type: char
FW …
Access: ro
Reading of the manufacturer's Internet address (ASCII, 7-bit). Fixed: “http://www.festo.com”
Unused characters are filled with zero (00
h
=’\0’).
Tab. B.17
PNU 123
PNU 124
Festo order number (Festo Order Number)
Subindex 1 … 30
Class: Array
Data type: char
FW …
Access: ro
Reading of the Festo order number/order code (ASCII, 7-bit).
With this specification, the user can order an identical device.
Unused characters are filled with zero (00h=’\0’).
Tab. B.18
PNU 124
Summary of Contents for CMMO-ST-C5-1-LKP
Page 182: ......