B Reference
paramete
130
Festo – GDCP-CMMO-ST-LK-C-HP-EN – 2017-05b – English
B.4.14
Project data – jog mode
PNU 530
Speed slow – phase 1 (Velocity Slow – Phase 1)
Subindex 1
Class: Var
Data type: int32
FW …
Access: rw2
Reading or parameterisation of the slow speed [SINC/s] for phase 1.
Tab. B.86
PNU 530
PNU 531
Speed fast – phase 2 (Velocity Fast – Phase 2)
Subindex 1
Class: Var
Data type: int32
FW …
Access: rw2
Reading or parameterisation of the max. speed [SINC/s] for phase 2.
Tab. B.87
PNU 531
PNU 532
Acceleration/deceleration (Acceleration/Deceleration)
Subindex 1
Class: Var
Data type: int32
FW …
Access: rw2
Reading or parameterisation of the acceleration/deceleration [SINC/s
2
] during jogging.
Tab. B.88
PNU 532
PNU 534
Time period phase 1 (Time Phase 1)
Subindex 1
Class: Var
Data type: uint16
FW …
Access: rw2
Reading or parameterisation of the time period [ms] for phase 1.
Tab. B.89
PNU 534
PNU 538
Following error message window (Following Error Window)
Subindex 1
Class: Var
Data type: int32
FW …
Access: rw2
Reading or parameterisation of the max. permitted following error.
Tab. B.90
PNU 538
PNU 539
Following error delay time (Following Error Timeout)
Subindex 1
Class: Var
Data type: uint16
FW …
Access: rw2
Reading or parameterisation of the damping time in [ms] of the following error monitoring.
Tab. B.91
PNU 539