PNU 438
Force comparator damping time (Force Comparator, Window Time)
Subindex 1 … 64
Class: Array
Data type: uint16
FW …
Access: rw1
Reading or parameterisation of the damping times [ms] of the force comparator.
Subindex 1 … 64
Record 1 … 64 (Record 1 … 64)
Force comparator damping time of the record 1 … 64.
Tab. B.72
PNU 438
PNU 439
Time comparator, min. (Time Comparator, Min.)
Subindex 1 … 64
Class: Array
Data type: uint32
FW …
Access: rw1
Reading or parameterisation of the lower limit values [ms] of the time comparator.
Subindex 1 … 64
Record 1 … 64 (Record 1 … 64)
Time comparator, min. of the record 1 … 64.
Tab. B.73
PNU 439
PNU 440
Time comparator, max. (Time Comparator, Max.)
Subindex 1 … 64
Class: Array
Data type: uint32
FW …
Access: rw1
Reading or parameterisation of the upper limit values [ms] of the time comparator.
Subindex 1 … 64
Record 1 … 64 (Record 1 … 64)
Time comparator, max. of the record 1 … 64.
Tab. B.74
PNU 440
PNU 441
Setpoint value speed (Setpoint Value Velocity)
Subindex 1 … 64
Class: Array
Data type: int32
FW …
Access: rw1
Reading or parameterisation of the end speed of a speed record. The sign of the value determines the
direction in which the speed is to be built up.
Subindex 1 … 64
Record 1 … 64 (Record 1 … 64)
End speed of the record 1 … 64.
Tab. B.75
PNU 441