75
Chapter 9
List of CMMB series motor controller parameters
9.1 F001
This panel menu contains all controller values which can be shown by the LED display when it’s in the
monitor mode (see 4.2) and no error or warning is shown. On the LED panel, select the panel address of the
value to be displayed and press SET. After leaving the menu, the selected value is displayed. To make this
selection permanent it must be saved through d2.00 in F002.
Table 9-1-1: Panel F001
Panel
address
Internal
address
Name
Description
Default
Range
R/W/
S
F001
2FF00408
Key_Address_F001
Internal value Panel value
0
d1.00
2
d1.02
4
d1.04
…
…
For d1.xx meaning please refer to
following table 9-1-2
25
/
RWS
Table 9-1-2: Panel F001 setting
Panel
address
Internal
address
Name
Description
Default
Range
RWS
d1.00
2FF00F20
Soft_Version_LED
Firmware version, display at the LED.
/
/
R
d1.02
2FF01008
Motor_IIt_Rate
Displays the rate of real iit and max iit
of the motor.
0
0-100%
R
d1.04
2FF01108
Driver_IIt_Rate
Display the rate of real iit and max iit
of the controller.
0
0-100%
R
d1.06
2FF01208
Chop_Power_Rate
Display the rate of real power and
rated power of the chopper.
0
0-100%
R
d1.08
60F70B10
Temp_Device
temperature of controller, unit:
℃
,
/
/
R
d1.09
60F71210
Real_DCBUS
DC bus voltage, unit: V,
/
/
R
d1.11
20100A10
Din_Real
Status of physical input
Bit 0: Din 1
Bit 1: Din 2
Bit 2: Din 3
…
/
/
R
d1.12
20101410
Dout_Real
Bit 0: Dout 1
Bit 1: Dout 2
Bit 2: Dout 3
…
/
/
R
d1.13
2FF01610
AN_V1
analog signal 1 voltage, unit 0.01V
/
/
R
d1.14
2FF01710
AN_V2
analog signal 2 voltage, unit 0.01V
/
/
R
d1.15
26010010
Error_State
See chapter 5.7, table5-7
0
0-65535
R
d1.16
26020010
Error_State2
See chapter 5.7, table5-8
0
0-65535
R