78
9.3 F003
This panel menu contains parameter for the configuration of analog and digital I/O functions.
Controller->Panel Menu->F003 DI/DO & Operation Mode Setting(F003)
Table 9-3: Panel F003 parameters
Panel
address
Internal
address
Name
Description
Default
Range
RWS
d3.00
2FF00108
Store_Data
Save or init parameters
1: save control parameters
10: init control parameters
0
0-255
RW
d3.01
20100310
Din1_Function
See chapter 6.1, table 6-1
0x0001 0-65535
RWS
d3.02
20100410
Din2_Function
See chapter 6.1, table 6-1
0x0002 0-65535
RWS
d3.03
20100510
Din3_Function
See chapter 6.1, table 6-1
0x2000 0-65535
RWS
d3.04
20100610
Din4_Function
See chapter 6.1, table 6-1
0x0010 0-65535
RWS
d3.05
20100710
Din5_Function
See chapter 6.1, table 6-1
0x0020 0-65535
RWS
d3.06
20100810
Din6_Function
See chapter 6.1, table 6-1
0
0-65535
RWS
d3.07
20100910
Din7_Function
See chapter 6.1, table 6-1
0x0040 0-65535
RWS
d3.10
20000008
Switch_On_Auto
0: no operation
1: auto-enable when logic power-up.
Can be set only if the DIN function
enable is not defined.
0
0-255
RWS
d3.11
20100F10
Dout1_Function
See chapter 6.1, table 6-2
0x0001 0-65535
RWS
d3.12
20101010
Dout2_Function
See chapter 6.1, table 6-2
0x0010 0-65535
RWS
d3.13
20101110
Dout3_Function
See chapter 6.1, table 6-2
0x0004 0-65535
RWS
d3.14
20101210
Dout4_Function
See chapter 6.1, table 6-2
0x0008 0-65535
RWS
d3.15
20101310
Dout5_Function
See chapter 6.1, table 6-2
0x0002 0-65535
RWS
d3.16
20200D08
Din_Mode0
Operation mode channel 0: select via
input port
-4
-128-127 RWS
d3.17
20200E08
Din_Mode1
Operation mode channel 1: select via
input port
-3
-128-127 RWS
d3.18
20200910
Din_Speed0_RPM
See chapter 6.2.2, table 6-8
unit: rpm
0
-32768-
32767
RWS
d3.19
20200A10
Din_Speed1_RPM
See chapter 6.2.2, table 6-8
unit: rpm
0
-32768-
32767
RWS
d3.20
20200B10
Din_Speed2_RPM
See chapter 6.2.2, table 6-8
unit: rpm
0
-32768-
32767
RWS
d3.21
20200C10
Din_Speed3_RPM
See chapter 6.2.2, table 6-8
unit: rpm
0
-32768-
32767
RWS
d3.22
25020110
Analog1_Filter
Filter parameter of analog signal 1
5
1-127
RWS
d3.23
2FF01D10
Analog1_Dead_V
Unit: 0.01V
0
-1000-
1000
RWS
d3.24
2FF01E10
Analog1_Offset_V
Unit: 0.01V
0
-1000-
1000
RWS
d3.25
25020410
Analog2_Filter
Filter parameter of analog signal 2
5
1-127
RWS