1
Safety and requirements for product use
8
Festo – GDCP-CAMC-G-S1-EN – 1412b – English
1
Safety and requirements for product use
1.1
Safety
1.1.1
General safety information
In addition, always observe the general safety regulations on the CMMP-AS-…-M3.
You will find the general safety regulations on the CMMP-AS-...-M3 in the hardware
documentation, GDCP-CMMP-M3-HW-...
è
Note
Loss of the safety function.
Non-compliance with environmental and connection conditions can lead to loss of the
safety function.
Observe the specified environmental and connection conditions, in particular the
input voltage tolerances
è
Note
Incorrect handling can damage the safety module or controller.
Before mounting and installation work, switch off the supply voltage. Switch on the
supply voltage only when the mounting and installation work is complete.
Never unplug a module from, or plug a module into the motor controller when it is
energised!
Observe the handling specifications for electrostatically-sensitive devices.
1.1.2
Intended use
The safety module CAMC-G-S1 serves as an expansion of the motor controller CMMP-AS-...-M3 to
achieve the safety function:
–
Safely switched-off torque – “Safe Torque Off ” (STO) with SIL3 according to EN 61800-5-2 /
EN 62061 / IEC 61508 or category 4 / PL e according to EN ISO 13849-1.
The motor controller CMMP-AS-...-M3 with safety module CAMC-G-S1 is a product with safety-relevant
functions and is intended for installation in machines or automation systems and for use as follows:
–
in a faultless technical condition,
–
in its original condition, without any modifications by the user,
–
within the product’s limits as defined by the technical data (
è
–
in an industrial environment.