4
Commissioning
Festo – GDCP-CAMC-G-S1-EN – 1412b – English
31
4
Commissioning
Note
Loss of the safety function!
Lack of the safety function can result in serious, irreversible injuries, e.g. due to
uncontrolled movements of the connected actuators.
Operate the safety module only:
–
in a built-in condition and
–
when all safety measures have been implemented.
Validate the safety function to complete commissioning
è
Incorrect wiring, use of an incorrect safety module or external components that were not
selected corresponding to the category, result in loss of the safety function.
Carry out a risk evaluation for your application and select the circuitry and components accordingly.
Note the examples
è
4.1
Before commissioning
Perform the following steps to prepare for commissioning:
1. Ensure that the safety module is correctly mounted (
è
2. Check the electrical installation (connecting cable, pin allocation
è
Section 3.2). Are all protective
earth conductors connected?
4.2
DIP switch setting
DIP switches for activating and controlling the fieldbus configuration are located on the safety module.
The functionality of the DIP switch is identical to that of the switch module CAMC-DS-M1 and independ
ent of the fieldbus interface used.
Set the DIP switches as described in the hardware documentation
GDCP-CMMP-M3-HW-... or the corresponding fieldbus-specific documentation
è