85
EN
Cod. 3542B230 - Rev. 00 - 02/2022
OMNIA S HYBRID H 3.2
• Insert the new board and reconnect the electrical connections.
fig. 59 -
fig. 60 -
13.6.4 Replacement of boiler fan
CAUTION
Disconnect the electrical power supply and close the gas tap upstream of the valve
• Remove the electrical connections for the fan.
• Loosen the screws “1” and the connection of the gas pipe“2”.
• Remove venturi tube “3”.
fig. 61 -
fig. 62 -
13.6.5 Replacement of boiler pressure transducer
NOTE
Before starting with the following instructions, we recommend organising pro-
tective devices to protect the inner parts and the boiler electric box from any
accidental water leaks.
• Drain the water of the heating circuit.
• Remove the pressure transducer connector “2” and the fastening clip “1”.
• Remove the pressure transducer “2”.
fig. 63 -