58
EN
Cod. 3542B230 - Rev. 00 - 02/2022
OMNIA S HYBRID H 3.2
Cool mode weekly schedule (Preset Temp. Cool)
User menu > Preset temp > Preset Temp Cool
The submenu with the 7 days of the week will appear, for each day there are 6 possible events to be set from Event 1 to Event 6 will appear.
Monday
Event 1
Enabled y/n
Enable the event
Event 2
Time
Start time hh:mm
Event 3
Temperature
Water temperature setpoint
Event 4
Event 5
Event 6
Heat mode weekly schedule (Preset Temp. Heat)
User menu > Preset temp > Preset Temp Heat
The submenu with the 7 days of the week will appear, for each day there are 6 possible events to be set from Event 1 to Event 6 will appear.
Monday
Event 1
Enabled y/n
Enable the event
Event 2
Time
Start time hh:mm
Event 3
Temperature
Water temperature setpoint
Event 4
Event 5
Event 6
The temperature setting remains active until the next enabled event. At the start of this new enabled event, the new associated temperature is set on the machine
and so on.
Climate curves (Weather Temp Set)
User menu > Preset temp > Weather Temp Set
The function allows you to set the water flow temperature set point for Heat mode and Cool mode as a function of the outside air temperature.
Z1 Cool Mode
Enabled y/n
Enables the climatic curve for zone 1 in cooling mode
Clim Curve Sel
to select the climatic curve in cooling mode
Z1 Heat Mode
Enabled y/n
Enables the climatic curve for zone 1 in heating mode
Clim Curve Sel
to select the climatic curve in heating mode
Z2 Cool Mode
Enabled
to select the climatic curve in cooling mode
Clim Curve Sel
to select the climatic curve in heating mode
Z2 Heat Mode
Enabled y/n
Enables the climatic curve for zone 2 in heating mode
Clim Curve Sel
to select the climatic curve in heating mode
When the climatic curves are enabled, it is not possible to modify the T1S set point manually and a warning message will appear.
Economy mode (Eco Mode)
User menu > Preset temp > Eco Mode
Enabled y/n
yes/no
enables the ECO function (not available for 2 zones)
Clim Curve Sel
1-9
select the climatic curve from 1 to 9
Timer enabled y/n yes/no
Enable the timer
Start
hh.mm
start time
End
hh.mm
end time
If
ECO mode
is enabled:
•
Timer = not enabled, ECO is always active.
•
Timer = enabled, the start and end times must be set
Anti-legionella (Disinfect)
User menu > Dhw settings > Disinfect
It allows to eliminate the Legionella bacteria. In the disinfect function, the tank temperature must reach 65~70°C.
The disinfect temperature and relevant times are set in the “For serviceman” menu (see “9.3.2 Heat pump service menu" on page 60).
Enabled y/n
yes/no
enables the anti-legionella disinfect function
Operate Day
Sunday/Monday
anti-legionella day week
Start
hh.mm
anti-legionella start time
When the anti-legionella function is working, the relative icon appears on the display.
Fast DHW filling (Fast Dhw)
User menu > Dhw settings > Fast Dhw
The function allows you to force all available system heat sources (heat pump, DHW boiler electric heater and gas boiler) to meet the domestic hot water set point as
soon as possible.
Once the setpoint is satisfied, the function is automatically disabled and remains disabled until it is called up manually.
DHW electric heater (TBH-Tank Heater)
User menu > Dhw settings > Tank Heater
The function allows you to force the heating of the water in the DHW tank with the TBH electric heater.
In case of simultaneous cooling / heating and DHW request, to guarantee both services, the heat pump will work for the plant and with the TBH electric heater for DHW.
If the temperature sensor (T5) of the DHW heater is faulty, the TBH electric heater cannot work.