OMNIA S HYBRID H 3.2
8.4
DHW and system set point configuration
SW1
SW5
SW2
SW3
SW4
SW6
SW7
NOTE
The icon indicates which setpoint is being
modified
DHW set point (min 30°C, max 60°C)
To change the
DHW set point
, proceed as follows:
•
press the SW1/SW2 buttons to select the set point
•
press the SW6/SW7 buttons to change the set point
•
confirm the modified value with the SW3 button
Single zone set point
Type of terminal selected
Heat setpoint (min:max)
Cool setpoint (min:max)
FLH (radiant floor)
25: 55
18: 25
FCU (fancoil) / RAD (radiator)
25: 65
5: 25
To change the
single zone set point
, proceed as follows:
•
press the SW1/SW2 buttons to select the set point
•
press the SW6/SW7 buttons to change the set point
•
confirm the modified value with the SW3 button
Zone Z1 set point
Type of terminal selected
Heat setpoint (min:max)
Cool setpoint (min:max)
FLH (radiant floor)
25: 55
18: 25
FCU (fancoil) / RAD (radiator)
25: 65
5: 25
To change the
zone Z1 set point
, proceed as follows:
•
press the SW1/SW2 buttons to select the set point
•
press the SW6/SW7 buttons to change the set point
•
confirm the modified value with the SW3 button
Z1
Zone Z2 set point
Type of terminal selected
Heat setpoint (min:max)
Cool setpoint (min:max)
FLH (radiant floor)
25: 55
18: 25
FCU (fancoil) / RAD (radiator)
25: 65
5: 25
To change the
zone Z2 set point
, proceed as follows:
•
press the SW1/SW2 buttons to select the set point
•
press the SW6/SW7 buttons to change the set point
•
confirm the modified value with the SW3 button
Z2