53
EN
Cod. 3542B230 - Rev. 00 - 02/2022
OMNIA S HYBRID H 3.2
Index Description
Modulation
Default
b18 DHW mode
activation flow rate
0-100L/min/10
25
b19 DHW mode
deactivation flow rate
0-100L/min/10
20
b20 Flue material selection
0 = Standard
1 = PVC
2 = CPVC
0
b21 Not implemented
--
--
b22 Not implemented
--
--
b23 Maximum temperature
standard flue switch off
60-110°C
105
b24 Maximum temperature
PVC flue switch off
60-110°C
93
b25 Maximum temperature
CPVC flue switch off
60-110°C
98
b26 Not implemented
--
--
b27 Calibration procedure [AUTO SETUP]
5 = Calibration procedure [AUTO SETUP] enabled
All other values = Calibration procedure [AUTO SETUP] disabled
0
b28 Not implemented
--
--
b29 Restore factory settings
Factory reset
0
P30 Heating ramp
0÷80
(e.g. 10=20°C/min, 20=12°C/min, 40=6°C/min, 80=3°C/min)
40
P31 Heating wait time
0-10 minutes
4
P32 Heat post circulation
0-255 minutes
15
P33 Pump operation
0 = Continuous pump (only active in winter mode)
1 = Modulating pump
1
P34 DeltaT pump modulation
0 ÷ 40°C
20
P35 Minimum speed modulating
pump
30 ÷ 100%
30
P36 Start speed modulating
pump
90 ÷ 100%
90
P37 Maximum speed modulating
pump
90 ÷ 100%
100
P38 Pump switch-off temperature
during post circulation
0 ÷ 100°C
55
P39 Pump switch-on hysteresis
temperature during post circulation
0 ÷ 100°C
25
P40 User heating maximum
setpoint
20 ÷ 90°C
80
P41 Maximum heating power
0 ÷ 100%
100
P42 Anti-Legionella function schedule
0 = OFF
1÷7 = Days
0
P43 Boiler hysteresis
0 ÷ 80°C
2
P44 Boiler delivery preparation
0 ÷ 100°C
80
P45 DHW wait time
30 ÷ 255 seconds
120
P46 User DHW maximum setpoint
40 ÷70°C
65
P47 DHW pump
post circulation
0 ÷ 255 seconds
30
P48 DHW maximum power
0 ÷ 100%
100
P49 Not implemented
--
--
P50 Not implemented
--
--
P51 Solar switch-off
temperature
--
10
P52 Not implemented
--
5
P53 Not implemented
--
10
P54 System pre-circulation time
0 ÷ 60 seconds
30
P55 System filling method
0 = Disabled
1 = Automatic
0
P56 System pressure minimum
limit value
0-8 bar/10 (Only for boilers with water pressure sensor)
4
P57 System pressure
rated value
5-20 bar/10 (Only for boilers with water pressure sensor)
7
P58 System pressure maximum
limit value
25-35 bar/10 (Only for boilers with water pressure sensor)
28
P59 Pump deactivation with OpenTherm
0 ÷ 1
(1 = Circulator deactivated with Open Therm)
0
P60 Antifreeze power
0 ÷ 50% (0 = minimum)
0