56
EN
Cod. 3542B230 - Rev. 00 - 02/2022
OMNIA S HYBRID H 3.2
Menu
Level 1
Menu
Level 2
Menu
Level 3
Menu
Level 4
Menu
Level 5
Description
Lower
limit
Upper
limit
Rem-
edy
Unit of
meas-
ure-
ment
Default
value
Dhw
Settings
Disinfect
Enabled y/n
yes/no
enable the anti-legionella disinfection function
YES
NO
/
/
NO
Operate Day Sunday/
Monday
anti-legionella day
Sunday Monday
/
/
Friday
Start
hh.mm
anti-legionella start time
00.00
23.59 1 min hh:mm 00.00
Fast Dhw state
Enabled Y/N yes/no
activates all the sources for fast DHW heating - the function is automatically
disabled and stays disabled when the setpoint is reached.
None / ON / OFF
/
/
None
Tank Heater state Enabled Y/N yes/no
activate the DHW boiler electric heating element
None / ON / OFF
/
/
None
Dhw Pump Circ
T1 Enabled
y/n
S t a r t
hh.mm
if yes, it is possible to set the start time and then the pump will operate for a time
defined in the parameter t_INTERVAL_DHW
YES
NO
/
/
NO
T2 Enabled
y/n
S t a r t
hh.mm
if yes, it is possible to set the start time and then the pump will operate for a time
defined in the parameter t_INTERVAL_DHW
YES
NO
/
/
NO
T3 Enabled
y/n
S t a r t
hh.mm
if yes, it is possible to set the start time and then the pump will operate for a time
defined in the parameter t_INTERVAL_DHW
YES
NO
/
/
NO
T4 Enabled
y/n
S t a r t
hh.mm
if yes, it is possible to set the start time and then the pump will operate for a time
defined in the parameter t_INTERVAL_DHW
YES
NO
/
/
NO
T5 Enabled y/n S t a r t
hh.mm
if yes, it is possible to set the start time and then the pump will operate for a time
defined in the parameter t_INTERVAL_DHW
YES
NO
/
/
NO
T6 Enabled
y/n
S t a r t
hh.mm
if yes, it is possible to set the start time and then the pump will operate for a time
defined in the parameter t_INTERVAL_DHW
YES
NO
/
/
NO
T7 Enabled
y/n
S t a r t
hh.mm
if yes, it is possible to set the start time and then the pump will operate for a time
defined in the parameter t_INTERVAL_DHW
YES
NO
/
/
NO
T8 Enabled
y/n
S t a r t
hh.mm
if yes, it is possible to set the start time and then the pump will operate for a time
defined in the parameter t_INTERVAL_DHW
YES
NO
/
/
NO
T9 Enabled
y/n
S t a r t
hh.mm
if yes, it is possible to set the start time and then the pump will operate for a time
defined in the parameter t_INTERVAL_DHW
YES
NO
/
/
NO
T10 Enabled
y/n
S t a r t
hh.mm
if yes, it is possible to set the start time and then the pump will operate for a time
defined in the parameter t_INTERVAL_DHW
YES
NO
/
/
NO
T11 Enabled
y/n
S t a r t
hh.mm
if yes, it is possible to set the start time and then the pump will operate for a time
defined in the parameter t_INTERVAL_DHW
YES
NO
/
/
NO
T12 Enabled
y/n
S t a r t
hh.mm
if yes, it is possible to set the start time and then the pump will operate for a time
defined in the parameter t_INTERVAL_DHW
YES
NO
/
/
NO
Options
Silent Mode
Enable Y/N
yes/no
enables silent mode
YES
NO
/
/
NO
Silent Level
1-2
to set silent level
0
2
1
/
0
Timer 1
Enable
it is possible to set the start time of timer 1
Yes
No
No
From Date
it is possible to set the end time of timer 1
0:00
24:00
0:00
Until date
enable timer 1 or not
0:00
24:00
0:00
Timer 2
Enable
it is possible to set the start time of timer 2
Yes
No
No
From Date
it is possible to set the end time of timer 2
0:00
24:00
0:00
Until date
enable timer 2 or not
0:00
24:00
0:00
Holiday
Enabled Y/N
activates holiday mode
YES
NO
/
/
NO
Dhw Mode On/
Off
to set if DHW is on/off during the holidays
ON
OFF
/
/
ON
Disinfect On/
Off
to set if the disinfect function is enabled/disabled during the holidays
ON
OFF
/
/
ON
Heat Mode
On/Off
to set if the heating mode is enabled/disabled during the holidays
ON
OFF
/
/
ON
From Date
first day of holiday
01/01/2000 01/06/2099
/
/
01/01/2021
Until Date
last day of holiday
01/01/2000 01/06/2099
/
/
01/01/2021
Backup Heater
state
Bckp Heat On/
Off
Enabling and disabling of back-up electric heater (1=ON - 2=OFF)
None / ON / OFF
/
/
None
Service
Informa-
tion
Parameters
Main Set Temp
system temp set point temp based on selected mode
5
65
1
°C
12 cooling
/ 40
heating
Main Actual
Temp
Water delivery temperature (TW_OUT)
/
/
1
°C
/
Tank Set Temp
Setpoint DHW heater (T5s)
30
60
1
°C
50
Tank Actual
Temp T5
Temperature DHW heater (T5)
/
/
1
°C
/
Smart Grid
Run Time
total daily run time of the smart grid
0
24
1
hh
/
Display
Date and time
to set the date and time
Hours
Min
Day
Month
Year
00-23
00-59
00-31
00-12
2000-2099
Contrast
on/off
to set the display contrast
MIN-2-3-4-5-6-7-8-9-MAX
5
Brightness
to set the display brightness
MIN-30%-40%-50%-60%-70%-
80%-90%-MAX
MAX
Backlight time
to set the start of the backlighting
1
10
1
min
2
Smart Grid
S.Grid Run
Time Set
set working time for SMART GRID
0
24
1
h
2
Error Code
Error List
Code
error code with date and time of the event
/
/
/
/
/
Date
date of the event
/
/
/
/
/
Hh.Mm
event time
/
/
/
/
/