Special instructions
4812159501_D.pdf
2018-04-12
When fitting batteries, always connect the
positive cable first.
When fitting batteries, always connect the
positive cable first.
Dispose of old batteries in an environmentally
friendly way. Batteries contain toxic lead.
Dispose of old batteries in an environmentally
friendly way. Batteries contain toxic lead.
Do not use a quick-charger for charging the
battery. This may shorten battery life.
Do not use a quick-charger for charging the
battery. This may shorten battery life.
Jump starting (24V)
Do not connect the negative cable to the
negative terminal on the dead battery. A spark
can ignite the oxy-hydrogen gas formed
around the battery.
Do not connect the negative cable to the
negative terminal on the dead battery. A spark
can ignite the oxy-hydrogen gas formed
around the battery.
Check that the battery used for jump starting
has the same voltage as the dead battery.
Check that the battery used for jump starting
has the same voltage as the dead battery.
24V
12V
12V
Fig. Jump starting
1
2
3
4
Turn the ignition and all power consuming equipment
off. Switch off the engine on the machine which is
providing jump start power.
Jump leads must have 24V.
First connect the jump start battery's positive terminal
(1) to the flat battery's positive terminal (2).Then
connect the jump start battery's negative terminal (3)
to, for example, a bolt (4) or the lifjting eye on the
machine with the flat battery.
Start the engine on the power providing machine. Let it
run for a while. Now try to start the other machine.
Disconnect the cables in the reverse order.
13
Summary of Contents for CC424CHF
Page 2: ......
Page 12: ...e 4812159501_D pdf 2018 04 12...
Page 16: ...Introduction 4812159501_D pdf 2018 04 12 4...
Page 26: ...Special instructions 4812159501_D pdf 2018 04 12 14...
Page 84: ...Operation 4812159501_D pdf 2018 04 12 72...
Page 98: ...Preventive maintenance 4812159501_D pdf 2018 04 12 86...
Page 118: ...Maintenance 10h 4812159501_D pdf 2018 04 12 106...
Page 122: ...Maintenance 50h 4812159501_D pdf 2018 04 12 110...
Page 126: ...Maintenance measures 250 h 4812159501_D pdf 2018 04 12 114...
Page 144: ...Maintenance 1000h 4812159501_D pdf 2018 04 12 132...
Page 157: ......
Page 158: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...