![Fayat CC424CHF Instruction Manual Download Page 128](http://html1.mh-extra.com/html/fayat/cc424chf/cc424chf_instruction-manual_4598990128.webp)
Maintenance measures - 500 h
4812159501_D.pdf
2018-04-12
3
6
4
5
2
Fig. Air cleaner
1. Clips
2. Cover
3. Main filter
4. Backup filter
5. Filter housing
6. Dust valve
1
Release the clips (1), pull off the cover (2), and pull out
the main filter (3).
Do not remove the backup filter (4).
Clean the air cleaner if necessary, see section Air
cleaner - Cleaning.
When replacing the main filter (3), insert a new filter
and refit the air cleaner in the reverse order.
Check the condition of the dust valve (6); replace if
necessary.
When refitting the cover, make sure that the dust valve
is positioned downwards.
Backup filter - Change
Fig. Air filter
1. Backup filter
1
Change the backup filter with a new filter after every
second replacement of the main filter.
To change the backup filter (1), pull the old filter out of
its holder, insert a new filter and reassemble the air
cleaner in the reverse order.
Clean the air cleaner if necessary, see section Air
cleaner - Cleaning.
116
Summary of Contents for CC424CHF
Page 2: ......
Page 12: ...e 4812159501_D pdf 2018 04 12...
Page 16: ...Introduction 4812159501_D pdf 2018 04 12 4...
Page 26: ...Special instructions 4812159501_D pdf 2018 04 12 14...
Page 84: ...Operation 4812159501_D pdf 2018 04 12 72...
Page 98: ...Preventive maintenance 4812159501_D pdf 2018 04 12 86...
Page 118: ...Maintenance 10h 4812159501_D pdf 2018 04 12 106...
Page 122: ...Maintenance 50h 4812159501_D pdf 2018 04 12 110...
Page 126: ...Maintenance measures 250 h 4812159501_D pdf 2018 04 12 114...
Page 144: ...Maintenance 1000h 4812159501_D pdf 2018 04 12 132...
Page 157: ......
Page 158: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...