Maintenance - 2000h
4812159501_D.pdf
2018-04-12
Backup filter - Change
Fig. Air filter
1. Backup filter
1
Change the backup filter with a new filter after every
second replacement of the main filter.
To change the backup filter (1), pull the old filter out of
its holder, insert a new filter and reassemble the air
cleaner in the reverse order.
Clean the air cleaner if necessary, see section Air
cleaner - Cleaning.
Air cleaner
- Cleaning
Wipe clean on both sides of the outlet
pipe.
Outer edge of outlet
pipe.
Inner edge of
outlet pipe.
Wipe clean the inside of the cover (2) and the filter
housing (5). See the previous illustration.
Wipe also both surfaces for the outlet pipe; see
adjacent figure.
Check that the hose clamps between the filter
housing and the suction hose are tight and that
the hoses are intact. Inspect the entire hose
system, all the way to the engine.
Check that the hose clamps between the filter
housing and the suction hose are tight and that
the hoses are intact. Inspect the entire hose
system, all the way to the engine.
134
Summary of Contents for CC424CHF
Page 2: ......
Page 12: ...e 4812159501_D pdf 2018 04 12...
Page 16: ...Introduction 4812159501_D pdf 2018 04 12 4...
Page 26: ...Special instructions 4812159501_D pdf 2018 04 12 14...
Page 84: ...Operation 4812159501_D pdf 2018 04 12 72...
Page 98: ...Preventive maintenance 4812159501_D pdf 2018 04 12 86...
Page 118: ...Maintenance 10h 4812159501_D pdf 2018 04 12 106...
Page 122: ...Maintenance 50h 4812159501_D pdf 2018 04 12 110...
Page 126: ...Maintenance measures 250 h 4812159501_D pdf 2018 04 12 114...
Page 144: ...Maintenance 1000h 4812159501_D pdf 2018 04 12 132...
Page 157: ......
Page 158: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...