Faithtech FT68200 Operation Manual
18
1.4.10. Performance Specification (48kW)
Model
FT68248A/E-150-2400
FT68248A/E-600-2400
FT68248A/E-1200-1920
voltage
150V
600V
1200V
Current
2400A
2400A
1920A
Power
48000W
48000W
48000W
U
min
@I
max
1.5V@2400A
14V@2400A
20V@1920A
Constant Current
Range
240A
2400A
240A
2400A
192A
1920A
Resolution 4mA
40mA
4mA
40mA
3.2mA
32mA
Accuracy
0.05%+0.05%F.S.
0.05%+0.05%F.S.
0.05%+0.05%F.S.
Constant Voltage
Range
30V
150V
120V
600V
240V
1200V
Resolution 0.5mV
2.5mV
2mV
10mV
4mV
20mV
Accuracy
0.025%+0.025%F.S.
0.025%+0.025%F.S.
0.025%+0.025%F.S.
Constant Resistance
Range
0.002
~
13
Ω
0.02
~
63
Ω
0.009
~
50
Ω
0.09
~
250
Ω
0.023
~
125
Ω
0.23
~
625
Ω
Accuracy
Vin/Rset*(0.2%)+0.2%IF.S
Vin/Rset*(0.2%)+0.2%IF.S
Vin/Rset*(0.2%)+0.2%IF.S
Constant Power
Range
48000W
48000W
48000W
Accuracy
0.2%+0.2% F.S.
0.2%+0.2% F.S.
0.2%+0.2% F.S.
Dynamic
T1&T2
10us
~
60S
10us
~
60S
10us
~
60S
Resolution 2us
2us
2us
Accuracy
1us+20PPM
1us+20PPM
1us+20PPM
Slew Rate
0.001
~
3A/us
0.01
~
30A/us
0.001
~
3A/us
0.01
~
30A/us
0.001
~
1.92A/us
0.01
~
19.2A/us
Current Measurement
Range
240A
2400A
240A
2400A
192A
1920A
Resolution 4mA
40mA
4mA
40mA
3.2mA
32mA
Accuracy
0.05%+0.05%F.S.
0.05%+0.05%F.S.
0.05%+0.05%F.S.
Voltage Measurement
Range
30V
150V
120V
600V
240V
1200V
Resolution 0.5mV
2.5mV
2mV
10mV
4mV
20mV
Accuracy
0.025%+0.025%F.S.
0.025%+0.025%F.S.
0.025%+0.025%F.S.
AC INPUT 220VAC±10%, (50
~
60)Hz , 2820VA
Temp
(0
~
40)
℃
Weight
312kg
Dimension 550.0mm(W) * 1161.0mm(H) * 716.0mm(L)
Summary of Contents for FT68200 Series
Page 9: ...Faithtech FT68200 Operation Manual 3 1 3 2 7U 8kW 10kW 12kW...
Page 10: ...Faithtech FT68200 Operation Manual 4 1 3 3 11U 14kW 16kW 18kW...
Page 11: ...Faithtech FT68200 Operation Manual 5 1 3 4 14U 20kW 22kW 24kW...
Page 12: ...Faithtech FT68200 Operation Manual 6 1 3 5 20U 30kW 36kW...
Page 13: ...Faithtech FT68200 Operation Manual 7 1 3 6 26U 42kW 48kW...
Page 14: ...Faithtech FT68200 Operation Manual 8 1 3 7 32U 54kW 60kW...